Mining Applications

Komatsu PC4000
Wheel Loader - Sound Attenuation

Colpro's mining projects and capabilities are focused on:

Colpro Engineering provide varied services for mining applications. They can provide simple secondary silencers or engine compartment lining. They also offer wholistic solutions for individual machinery, with the use of acoustic modelling and noise intensity surveys, to achieve acoustic targets.

Colpro has designed and supplied acoustic treatment to almost all types and sizes of above ground mining machinery. Bellow is a small summary of projects to show the range of applications.

Summary of Mining Projects

These are examples of Colpro's  past involvements and capabilities:

Haul Trucks
Primary and secondary exhaust silencers to suit a fleet of 320 tonne haul trucks at Mt Arthur Coal Mine. Colpro worked closely with OEM to “tune” the silencers to target particular frequencies. This allowed the trucks to meet their overall sound power as well as frequency spectrum requirements.


Full Acoustic Treatment to fleet of 190 tonne haul trucks at Muswellbrook Coal. Working with OEM proprietary designs, Colpro created acoustic models to help design and predict acoustic treatment to lower the sound power of the haul trucks. Treatment included:

  • High performance exhaust silencer
  • GE grid box attenuation
  • Radiator attenuators
  • Rear axle fan attenuator
  • Side doors and belly pan

Side doors and belly pan feature excellent access for maintenance. No issues with overheating to date.

Excavators
30m3 excavator at Bengalla Mine. Colpro was responsible for lowering the sound power to meet the contract specification. Colpro designed, fabricated and installed:

  • Walkthrough rear counterweight enclosure
  • Hydraulic and engine intake and discharge attenuators
  • Engine room and hydraulic room wall lining
  • Floor, wall and roof panelling

Acoustic treatment is integrated to the profile of the machine. Slewing radius and maintenance access is unaffected.

Acoustic treatment of 16m^3 excavator at Mt Owen mine. Conducted sound intensity survey with an acoustic model of the machine. Designed, fabricated and installed:

  • High performance exhaust silencers with dust extraction venturi
  • Engine cooler attenuator
  • Hydraulic cooler attenuator
  • Engine and hydraulic compartment lining
  • Acoustic door to hydraulic compartment

Loaders
25 tonne wheeled loader at Bengalla mine. Designed, fabricated and installed the following acoustic treatment:

  • Exhaust silencers
  • Side doors
  • Hinged rear radiator attenuator
  • Engine compartment lining
  • Minor panelling
1.7 cubic meter wheeled loader. Colpro designed fabricated and installed engine compartment lining, Secondary exhaust silencer and rear radiator attenuator (not shown).

HOME

Copyright © 2000-08 Colpro Engineering (Australia) Pty Limited. 
Phone: 61 2 9896 0422  Email: info@Colpro.com.au

Web Design by WebStart Design